Power Supply

POWER SUPPLY
Switched voltage (Term. 15) is supplied to the Transmission Control Module, terminal 19, to power the TCM. This power supply is not fused.

SELF-DIAGNOSIS
After the engine starting sequence, if supply voltage goes below 9.0 volts, the transmission will go into Emergency Running Mode.