LEMON Manuals: Even more car manuals for everyone
Home >> Eagle >> 1995 >> Summit L4-1468cc 1.5L SOHC >> Repair and Diagnosis >> Starting and Charging >> Charging System >> Alternator >> Rectifier Diode / Bridge >> Testing and Inspection >> Diode Trio Test

Diode Trio Test

Diode Trio Test:





Check three diodes for continuity by connecting an ammeter to both ends of each diode. If there is no continuity in both directions, diode is faulty and heatsink assembly must be replaced.